Fuel Cell & Hydrogen

Description

voiture-hybride-ref-2351

The storage of hydrogen and the development of fuel cells are one of the main issues for the development of renewable energies in the next few years. Different groups of materials have the potentiality to store and release hydrogen:
–    carbon : nanotubes and graphite nanofibers
–    other high surface area materials :
– H2O-reactive chemical hydrides: zeolites, gas hydrates, metal oxide frameworks (MOFs)
– thermal chemical hydrides
– rechargeable hydrides borohydrides, alanates, amides.

The R&D issues that can be followed by the calorimetric techniques are to find lower desorption temperatures, higher desorption kinetics, optimization of the recharge time and pressure, heat management, cyclic life, optimization of the storage capacity.

Some International References
LCMTR Thiais – France
TU Bergakademie Freiberg – Germany

 

Associated products

TGA, from ambient to 1150°C or 1600°C

LABSYS evo TGA

LABSYS evo is a user friendly, robust and highly powerful thermal analysis platform. HIGHLIGHTS include: • A comprehensive line of thermal analyzers with two temperature ranges chosen and optimized for distinct families of application: – RT – 1 150 °C, a cost effective solution mostly (but not only)...

Read more »

TGA, and Simultaneous TGA-DTA, TGA-DSC from ambient to 1150°C or 1600°C

LABSYS evo STA

LABSYS evo is a user friendly, robust and highly powerful thermal analysis platform. HIGHLIGHTS include: • A comprehensive line of thermal analyzers with two temperature ranges chosen and optimized for distinct families of application: – RT – 1 150 °C, a cost effective solution...

Read more »

High-performance simultaneous TGA & DTA / DSC (ambient / 2400°C) with Evolved Gas Analysis

SETSYS Evolution TGA/STA-EGA

  The HIGHLIGHTS SETSYS Evolution is the standard for high performance TGA, TG-DSC and TG-DTA application.  It is based on a complete modular thermal analysis platform for – TGA, DTA and DSC – Simultaneous TGA/DTA and TGA/DSC – The key to...

Read more »

TGA-EGA and Simultaneous STA-EGA, from ambient to 1150°C or 1600°C

LABSYS evo TGA/STA-EGA

THE HIGHLIGHTS Simplicity of use: thanks to both an ergonomic design and the dedicated market leading Calisto software, LABSYS evo is user friendly and intuitive to operate – LABSYS evo offers a “Plug & play” gas analyzer coupling device,enabling simultaneous MS, FTIR or GC/MS connections....

Read more »

Stand-alone High Pressure Mass Spectrometer for gas composition analysis from 200 bar to 10-8 mtorr

RGAPro

Stand-alone High Pressure Mass Spectrometer for gas composition analysis from 200 bar to 10-8 mtorr The RGAPro is a residual gas analyzer designed to work with the PCTPro-2000 or any other gas process for real-time compositional analysis of gas sorption and reaction processes. The system uses a 100 to 300 amu quadrupole mass spectrometer with...

Read more »

An innovative line of Thermal Analyzers (-120 / 830°C) with 3D-Inside technology: DSC, High Pressure DSC, Robot DSC, TG - DSC - coupling to gas analyzer

SENSYS evo DSC

An innovative line of Thermal Analyzers (-120 / 830°C) with 3D-Inside technology: DSC, High Pressure DSC, Robot DSC, TG – DSC – coupling to gas analyzer The HIGHLIGHTS Incomparable precision: the unique 3D sensor totally surrounds your sample and reference crucibles so that the entire energy of any transformation is monitored thereby giving you an...

Read more »

An innovative line of Thermal Analyzers (-120 / 830°C) with 3D-Inside technology: DSC, High Pressure DSC, Robot DSC, TGA-DSC-coupling to gas analyzer

SENSYS evo TGA-DSC

The HIGHLIGHTS Differential Scanning Calorimeter – Incomparable precision: the unique 3D DSC sensor totally surrounds your sample and reference crucibles so that the entire energy of any transformation is monitored thereby giving you...

Read more »

A fully automated Sieverts instrument for measuring gas (CO2, CH4, C2H6, N2, H2) sorption properties of materials

PCTPro

The PCTPro is based on the Sievert’s method. A sample at known pressure and volume is connected to a reservoir of known volume and pressure through an isolation valve. Opening the isolation valve allows new equilibrium to be...

Read more »

An innovative line of Thermal Analyzers (-120 / 830°C) with 3D-Inside technology: DSC, High Pressure DSC, Robot DSC, TG-DSC-coupling to gas analyzer

SENSYS evo TG-DSC

The HIGHLIGHTS Differential Scanning Calorimeter – Incomparable precision: the unique 3D DSC sensor totally surrounds your sample and reference crucibles so that the entire energy of any transformation is monitored thereby giving you...

Read more »

High-performance modular DTA & DSC thermal analyzers (ambient / 2400°C)

SETSYS Evolution DTA/DSC

The HIGHLIGHTS SETSYS Evolution is the standard for high performance TGA, TG-DSC and TG-DTA application.  It is based on a complete modular thermal analysis platform for – TGA, DTA and DSC – Simultaneous TGA/DTA and TGA/DSC – Dilatometry / TMA The key to the SETSYS...

Read more »

Documentation

Brochures
Application notes
Articles See articles